Products - ECOM - UV-VIS Detectors |
|
UV/UV-VIS detectors for HPLC, Flash and preparative chromatography |
UV-VIS detectors for HPLC analytical, preparative and Flash chromatography applications. With variable wavelength, with fixed wavelength(interference filter), DAD, OEM - built-in, for high flow-rate, for CE - capillary electrophoresis, with fiber optics and interference filters. |
|
Overview |
|
UV-VIS HPLC detectors overview |
|
|
|
Variable wavelength 190-800nm |
|
SAPPHIRE 800 UV-VIS Variable Wavelength DETECTOR
Programmable wavelength change 190 up to 800 nm |
Cat. 6700000X |
|
|
SAPPHIRE 600 UV-VIS Variable Wavelength DETECTOR
Programmable wavelength change 190 up to 600 nm |
Cat. 67SH000X |
|
|
SAPPHIRE 800 CE Detector for Capillary Electrophoresis
Programmable wavelength adjusting 190 up to 800nm, application for capillary electrophoresis. |
Cat. 67CE000X |
|
|
SAPPHIRE 600 CE Detector for Capillary Electrophoresis
Programmable wavelength adjusting 190 up to 600nm, application for capillary electrophoresis |
Cat. 67SHCE0X |
|
|
SAPPHIRE 800 Ex Detector with optical connectors
UV-VIS Detector with variable wavelength 190 up to 800nm and optical connectors. |
Cat. 67EX000X |
|
|
SAPPHIRE 600 Ex Detector with optical connectors
UV-VIS Detector with variable wavelength 190 up to 600nm and optical connectors. |
Cat. 67SHEX0X |
|
|
PDA 200-900nm |
|
Flash 10 DAD 800 Detector
Four wavelengths simultaneously, display, keypad, 4 analog outputs, scan of whole spectrum 200-840nm |
Cat. 2053E00X |
|
|
Flash 10 DAD 600 Detector
Four wavelengths simultaneously, display, keypad, 4 analog outputs, scan of whole spectrum 200-600nm |
Cat. 2053B00X |
|
|
Flash 10 DAD 400 Detector
Four wavelengths simultaneously, display, keypad, 4 analog outputs, scan of whole spectrum 200-400nm |
Cat. 2053A00X |
|
|
Flash 06S DAD 800 Detector in housing
Four wavelengths simultaneously, scan of whole spectrum 200 - 840 nm |
Cat. 2052S00X |
|
|
Flash 06S DAD 600 Detector in housing
Four wavelengths simultaneously, scan of whole spectrum 200 - 600 nm |
Cat. 2050S00X |
|
|
Flash 06S DAD 400 Detector with housing
Four wavelengths simultaneously, scan of whole spectrum 200 - 400 nm |
Cat. 2046S00X |
|
|
Flash 06S DAD 600 EX Detector
Four wavelengths simultaneously, scan of spectrum 200-600nm. External cell. Std. power source. |
Cat. 2050EX0X |
|
|
Flash 06S DAD 800 EX Detector
Four wavelengths simultaneously, scan of spectrum 200-840nm. External cell. Std. power source. |
Cat. 2052EX0X |
|
|
Fixed wavelength 200-800nm |
|
OPAL Fixed Wavelength Detector
One fix wavelength given by chosen interference filter in range 200-600 mn. Interference filter determining wavelength is ordered separately. |
Cat. 65000000 |
|
|
OPAL VIS Fixed Wavelength Detector with LED
For VIS range (350-900 nm) with LED diode as light source. |
Cat. 65LD000000 |
|
|
Flash 06S Single Detector with housing
One fix wavelength given by chosen interference filter in range 200-600 mn |
Cat. 2048S00000 |
|
|
Flash 06S Dual Detector with housing
Two wavelengths simultaneously, according chosen interference filters in range 200 - 600 nm |
Cat. 2047S00000 |
|
|
OPAL EX Detector with Optical Connectors
UV-VIS Detector with fixed wavelength and optical connectors. Interference filter determining wavelength is ordered separately. |
Cat. 65EX000000 |
|
|
Built-in FlashDAD, SINGLE, DUAL |
|
Flash 06 DAD 400 Detector
Four wavelengths simultaneously, scan of whole spectrum 200 - 400 nm |
Cat. 2046000000 |
|
|
Flash 06 DAD 600 Detector
Four wavelengths simultaneously, scan of whole spectrum 200 - 600 nm |
Cat. 2050000001 |
|
|
Flash 06 DAD 800 Detector
Four wavelengths simultaneously, scan of whole spectrum 200 - 840 nm |
Cat. 2052000000 |
|
|
Flash 06 Single Detector
One fix wavelength given by chosen interference filter in range 200-600 mn |
Cat. 2048000000 |
|
|
Flash 06 Dual Detector
Two wavelengths simultaneously, according chosen interference filters in range 200 - 600 nm |
Cat. 2047000000 |
|
|
UV-VIS Detectors with high flow cell |
|
UV-VIS Detectors with high flow cell
ECOM designed SAPPHIRE UV-VIS Variable Wavelength Detector version, suited for CE (Capillary electrophoresis). Cell for quartz capillaries implementation is located at detector front panel. |
|
|
|
CE for capillary electrophoresis |
|
Detectors for capillary electrophoresis
ECOM designed SAPPHIRE UV-VIS Variable Wavelength Detector version, suited for CE (Capillary electrophoresis). |
|
|
|
CE for capillary electrophoresis |
|
UV-VIS Detectors with optical connectors
ECOM produce variants of detectors for external cell connecting. The cell is connected using fiber optic cable with SMA connectors. |
|
|
|
CE for capillary electrophoresis |
|
UV-VIS Detectors with optical connectors
Four cells, 190 up to 360 nm, without recorder |
Cat. 72000002 |
|
|
Interference filters |
|
Interference filter 200nm |
Cat. 200 IF 13-0.5 |
|
|
Interference filter 214nm |
Cat. 214-12-0.5-M |
|
|
Interference filter 228nm |
Cat. 228FS10-12.5 |
|
|
Interference filter 254nm |
Cat. 254-12-0.5-M |
|
|
Interference filter 280nm |
Cat. 280-10-0.5-M |
|
|
Interference filter 297nm |
Cat. 297FS10-12.5 |
|
|
Interference filter 313nm |
Cat. 312.6-10-0.5-M |
|
|
Interference filter 340nm |
Cat. 340-10-0.5-M |
|
|
Interference filtr 460nm |
Cat. 460-12-0.5-M |
|
|
Interference filter 560nm |
Cat. 560-10-0.5-M |
|
|
|
Top |
|